Pantograph-Catenary Relation R&D And Test Bench
Brief Introduction/Functions Simulate the actual operating conditions of vehicle power supply and current collection systems, and conduct experimental research on power supply and current collection systems of different forms and systems. Study the dynamic characteristics and quality of power supply and current collection system, and the safety, reliability, and compatibility of power supply and current collection systems Product Parameters/Key Technologies Simulated operating speed: no less than 550km/h, and maximum speed: 600km/h Working height of pantograph (free height): 1.5m-2.0m Power supply: AC25kV, 17.5kV to 32kV adjustable; ACAC0-200V; DC power supply: DC 600-2000V; Maximum frequency of horizontal/vertical excitation: 100Hz Maximum amplitude of horizontal/vertical excitation: 100mm Maximum acceleration of horizontal/longitudinal excitation: 15g Maximum angle when shaking, bowing, and side rolling: ± 5 ° Application Cases Mainly apply to research and development, promotion, production as well as maintenance and repair etc. of manufacturers, scientific research institutes, and universities in rail transit industry. |